Fire-resistant glass withstands fire for a defined period and thus secures escape and rescue routes. Unlike closed fire protection elements, it keeps visual contact in everyday use — for orientation, for daylight and for an open sense of space in stairways, corridors and foyers. Fire-resistant glass thus combines a strict safety requirement with architectural transparency that no opaque building element can provide.
For architects and planners, this glazing is also one of the trickiest glass decisions: where it is required, it is regulated by building law, and it may only be used as a complete system with an approval. Mistakes in the class, choice of frame or connection do not show in everyday use — but only in a fire or at acceptance.
The protection goal: gaining time
Fire protection in construction pursues a clear goal: people must be able to escape, and the fire brigade must be able to intervene effectively. Glazing in escape and rescue routes, in fire walls and between fire compartments prevents fire and smoke from spreading unhindered. The required fire resistance period — 30, 60, 90 or 120 minutes — is the time for which the element must withstand the fire so that this protection goal is achieved.
That is precisely why the class is not a design option but a requirement from the building’s fire safety strategy. It is fixed before frame material, format or appearance are discussed.
Classification to EN 13501-2
The performance of fire-resistant glazing is classified at European level to EN 13501-2. The letters describe what the element achieves, the number the period in minutes:
| Class | Meaning |
|---|---|
| E | Integrity — holds back flames and hot gases |
| EW | Integrity + limited heat radiation |
| EI | Integrity + insulation (limited temperature rise on the side away from the fire) |
EI 90 glazing withstands fire for 90 minutes and at the same time limits the temperature rise on the side away from the fire. Under the Model Administrative Provisions – Technical Building Rules (MVV TB), glazing that does not prevent the passage of heat radiation may only be used where there are no concerns with regard to rescuing people and effective firefighting. For the walls of escape corridors (notwendige Flure), it names as a solution fire-resistant glazing that also prevents the passage of heat radiation.
In practice, planners still encounter the German designations to DIN 4102-13: F glazing (e.g. F30, F90) prevents the spread of fire and smoke and the passage of heat radiation; it corresponds approximately to the EI class. G glazing (e.g. G30) only prevents the spread of fire and smoke and merely impedes heat radiation; it corresponds approximately to the E class. There is no official conversion. Anyone refurbishing existing buildings or reading older tender documents should be able to translate reliably between the two systems.
How fire-resistant glass works
Fire resistance is created by the glass build-up — and this differs fundamentally depending on the required performance.
EI glass consists of several panes with clear fire-resistant interlayers between them, such as gel or intumescent layers. In normal conditions these layers are crystal clear. When exposed to heat they foam up, become opaque and form an insulating barrier that limits the temperature rise on the side away from the fire.
E glass is, for example, special toughened soda lime silicate or borosilicate glass, wired glass, glass ceramics or laminated build-ups. It holds back flames and hot gases but lets heat radiation through. EW glazing limits radiation. Whether an element achieves EW also depends on the area and format of the tested glazing, not on the glass alone.
The types in detail
- F/EI glazing: integrity with insulation. The MVV TB names it, for example, for the walls of escape corridors; it is the choice where people escape past the pane in a fire.
- Glazing without insulation: for fire-resistant glazing, the MVV TB contains no assignment of the European classes E and EW. G glazing to DIN 4102-13, which does not prevent heat radiation, is only permitted where there are no concerns with regard to rescuing people and effective firefighting.
- All-glass systems with fire protection: largely frameless systems are tested up to integrity and insulation for 120 minutes — with correspondingly demanding detailing.
- Fire doors: in fire-resistant glazing of escape corridors, the doors must be tight-closing and self-closing and match the fire resistance period of the glazing.
Applications
Fire-resistant glass is used wherever the building regulations call for elements with fire resistance and transparency is wanted at the same time:
- Escape corridors and rescue routes: visual connection and daylight in everyday use, without giving up the fire resistance of the wall. EI glass itself becomes opaque in a fire.
- Stairways and fire compartments: glazing separates fire compartments without darkening the stairway.
- Fire walls with a view through: in internal fire walls, fire-resistant glazing is only permitted if it is limited to the number and size required for the use.
- Partition walls between separate units of use: for example between commercial units, medical practices or hotel areas.
- External walls and overhead glazing: in external walls where suitability has been demonstrated; sloping and horizontal fire-resistant glazing is possible with special systems.
Multifunction: fire protection combined
Fire protection rarely stands alone. In practice, one pane often has to meet several requirements at once:
- Fire protection + sound insulation in inner-city buildings and hotels
- Fire protection + solar control in façades with a high proportion of glass
- Fire protection + barrier protection for floor-to-ceiling glazing and balustrades
- Fire protection + burglar resistance at security-relevant transitions
Such build-ups are possible but must be covered by the system’s approval. Burglar resistance is only available where separate test results exist for it, and barrier fire-resistant glazing is additionally verified to DIN 18008-4. Early coordination prevents requirements from turning out to be incompatible only during construction.
Selection: the right class
Three questions lead to the right glazing:
- Which class does the fire safety strategy require? It is binding — not wishful thinking.
- Does the glazing have to prevent heat radiation? The MVV TB names such glazing for the walls of escape corridors; without this protection, glazing is only permitted where there are no concerns with regard to rescuing people and firefighting.
- Which additional functions are required? Sound, solar control, barrier protection or burglar resistance also determine the build-up and approval.
Frame and system: only tested counts
The most important principle: fire-resistant glass only works as part of a system, usually made up of panes, seals, glazing beads, frames and fixings. A single pane proves nothing on its own — what may be used is the complete construction covered by its approval, in Germany usually a general construction technique permit (aBG) of the German Institute for Building Technology (DIBt).
Each system has its own approval with its own limits for format and class. Components from different systems cannot be mixed at will.
Typical construction errors
- Glass and frame from different systems combined — the combination is not covered by the approval.
- Glazing without protection against heat radiation installed where EI or F would be required.
- Maximum format of the approval exceeded.
- Missing or faulty connections: the adjoining elements must maintain integrity for at least the same period.
Costs and cost-effectiveness
There is no reliable flat-rate price for fire-resistant glass; it depends on the tested system, i.e. on the class, format, frame and additional functions. The most important cost lever is the right class: a higher class than required goes beyond the requirement without bringing anything for it. A class that is too low does not meet the requirement.
Maintenance
Under the building regulations, fire-resistant glazing must be maintained so that it fulfils its purpose. The system may only be modified as its approval permits; repairs follow the original specification of the system. If this can no longer be determined, trade associations recommend replacing the entire system with a new one that has an approval.
Understanding approvals and permits
Whether fire-resistant glazing may be used is decided by its approval. Fire-resistant glazing is a construction technique for walls or parts of walls made of glass for which there are no generally recognised technical rules. This means:
- General construction technique permit (aBG) of the DIBt: usually required, also as a so-called combined notice together with a national technical approval (abZ).
- Project-related construction technique permit (vBG): issued by the supreme building authority if the construction deviates significantly from the general approval.
- National test certificate (abP): not sufficient for non-load-bearing internal partition walls made of glass.
European Technical Assessments (ETA) can also be issued for the corresponding products. What counts on site in the end is that the installed construction matches the approval and that conformity has been confirmed. A deviation that is not significant also counts as conformity; a significant deviation needs its own approval. We check the chain of approvals before the tender — and not only when the pane is already in place.
Fire protection in existing and listed buildings
Fire-resistant glass is particularly demanding in refurbishment. Existing stairways, fire walls and historic windows often have to be upgraded retrospectively without destroying the character of the building. This calls for slim profiles, delicate glazing-bar designs and detailing that suits listed buildings — while fully meeting the required fire resistance class.
Several requirements often collide: fire protection meets heritage protection, energy-efficient refurbishment and limited installation depths in existing buildings. We put these requirements in order, check which systems with an approval fit into the existing construction, and mediate between the heritage authority, the fire safety consultant and the contractor.
Our role
We coordinate the glazing with the fire safety strategy, check whether the classification, frame material and connection details fit together, and document the selection in a traceable way — as a reliable basis for tender, award and acceptance. Independent of manufacturers, compliant with standards and with an eye on cost-effectiveness.